Serial port / parallel port operations for Visual Basic 6.0

Although VB6 is no longer used, these examples are included because it is simple to learn.
In particular, we provide detailed guides on how to use and program hardware components such as parallel ports (LPT) and serial ports (COM).Below you can find a simple Visual Basic code example that checks the availability of serial and parallel ports and reports the number of available ports.
Functions to find out whether parallel and serial ports exist.
If the return values ​​are True, the port is available.
 

Function to Find Serial Port

Function IsComPortAvailable(ByVal portNum As Integer) As Boolean
    Dim fnum As Integer
    On Error GoTo ErrorHandler
    
    fnum = FreeFile
    Open "COM" & CStr(portNum) For Binary Shared As #fnum
    Close #fnum
    
    IsComPortAvailable = True
    Exit Function

ErrorHandler:
    If Err.Number <> 0 Then
        IsComPortAvailable = False
        Err.Clear
    End If
End Function

Function to find parallel port

Function IsLptPortAvailable(ByVal portNum As Integer) As Boolean
    ' Dosya numarasını tutacak bir değişken tanımla
    Dim fnum As Integer

    ' Çalışma zamanı hatalarını bastır
    On Error Resume Next

    ' Boş bir dosya numarası al
    fnum = FreeFile

    ' Belirtilen LPT portunu ikili paylaşımlı erişim için açmayı dene
    Open "LPT" & CStr(portNum) For Binary Shared As #fnum

    ' Portu açarken bir hata olup olmadığını kontrol et
    If Err = 0 Then
        ' Port başarıyla açıldıysa, portu kapat
        Close #fnum
        ' Portun kullanılabilir olduğunu belirten dönüş değerini True yap
        IsLptPortAvailable = True
    End If
    ' Hata varsa, fonksiyon varsayılan olarak False dönecek
End Function

We must call the above functions to find the number of ports.
It is not mandatory to use these functions.

For Serial Ports

Dim count As Integer, i As Integer
' 1'den 16'ya kadar olan port numaraları için döngü başlat
For i = 1 To 16
    ' Eğer mevcut bir COM portu varsa, sayacı artır
    If IsComPortAvailable(i) Then count = count + 1
Next
' Bulunan COM port sayısını mesaj kutusunda göster
MsgBox count & " adet seri port bulundu"

For Parallel Ports

Dim count As Integer, i As Integer

' 1'den 16'ya kadar olan port numaraları için döngü başlat
For i = 1 To 16
    ' Eğer mevcut bir LPT portu varsa, sayacı artır
    If IsLptPortAvailable(i) Then count = count + 1
Next

' Bulunan LPT port sayısını mesaj kutusunda göster
MsgBox count & " adet paralel port bulundu"

For operation on parallel or serial ports.

‘Once the current Port number is learned, it is opened using this function.
The fnum variable is the port number known to be open.Here, only the necessary part should be changed for LPT.
For COM, only the necessary part should be changed.

Public Sub OpenPort(ByVal PortNum As Integer)
    ' Dosya numarasını tutmak için bir değişken tanımla
    Dim fnum As Integer
    
    ' Boş bir dosya numarası al
    fnum = FreeFile
    
    ' Belirtilen LPT bağlantı noktasını çıktı modu ile aç
    Open "LPT" & CStr(PortNum) For Output As #fnum
    
    ' Dosya numarasını global veya modül seviyesindeki bir değişkene ata
    FileNumber = fnum
End Sub

‘The string variable is sent to the opened port with this function.

Public Sub SendToPort(ByVal PortNum As Integer, ByVal Data As Byte)
    ' Belirtilen dosya numarasına (LPT portu) veriyi yaz
    Write #CStr(FileNumber), Data
End Sub
Public Sub ClosePort(ByVal PortNum As Integer)
    Close #CStr(PortNum)'İşimiz bittiğinde portun kapatılması gereklidir.
End Sub